Electrical Engineering Manager | Genser Energy | Takoradi
Genser Energy Ghana Limited (GEGL)
- Sekondi-Takoradi, Western Region
- Permanent
- Full-time
Design Management:
- Oversee and manage all engineering design activities, including conceptual, FEED (Front End Engineering Design), basic, and detailed design phases:
- Advanced Process Control (APC).
- Distributed Control Systems (DCS).
- Programmable Logic Controllers (PLC).
- Supervisory Control and Data Acquisition (SCADA).
- Oversee the conceptualization, detailed design, and engineering calculations, ensuring compliance with technical specifications, codes, and standards:
- Design Documents.
- Hazardous Area Calculations.
- I/O Schedules.
- Loop Diagrams.
- Layout Drawings.
- Interconnection and Wiring Diagrams.
- Review Authorized For Construction drawings (AFCs), P&IDs, and commissioning checklists.
- Review all Red Lines and As Built Drawings to confirm accuracy and compliance with original designs and modifications.
- Ensure that warranty and punch list issues are effectively managed after commissioning.
- Implement and follow timelines, build detailed Gantt charts.
- Ensure designs comply with industry codes, standards, regulations, and safety requirements.
- Coordinate the integration of multidisciplinary design disciplines (e.g., mechanical, electrical, instrumentation, civil) to achieve cohesive project execution.
- Ensure that all designs are optimized for cost, efficiency, and operability while maintaining the highest quality and safety standards.
- Review and approve design changes, deviations, and design risk assessments.
- Manage the preparation of engineering schedules, budgets, and manpower forecasts, ensuring efficient utilization of resources.
- Monitor project progress against key milestones and design deliverables, identifying and mitigating risks or delays.
- Act as the main point of contact for all design-related aspects of the project, collaborating closely with project managers, engineering teams, and clients.
- Coordinate with other departments such as procurement, business development, and operations to ensure seamless project execution.
- Provide technical guidance as needed for the Operations & Maintenance teams on-site.
- Ensure design teams are adequately resourced and managed to meet project requirements and deadlines.
- Promote a culture of continuous improvement, encouraging innovation and the adoption of best practices.
- Interface with clients, vendors, and external stakeholders to understand design requirements, present technical solutions, and address concerns.
- Provide technical support during client meetings, offering design solutions that align with the client’s objectives and regulatory requirements.
- Ensure that the design team delivers designs that are practical, sustainable, and meet client expectations.
- Assist with the preparation of technical proposals and presentations for potential clients.
- Identify design risks early in the project and implement mitigation strategies.
- Ensure that all design work adheres to relevant industry standards, environmental regulations, and safety codes.
- Manage the design review process, ensuring compliance with both internal and external regulatory requirements.
- Stay abreast of industry trends, new technologies, and design innovations, integrating these advancements into project work as appropriate.
- Drive the adoption of new tools, technologies, and methodologies to improve design efficiency and effectiveness.
- Evaluate design performance and propose improvements for future projects.
- Supervise the team to execute assigned projects within deadlines and budget.
- Develop and implement necessary measures to ensure flexible work practice and team building.
- Carry out performance appraisals and development plans (including training) with subordinate staff.
- Implement training and development program for staff in line with the organization's technical and business needs.
- Coordinate the rotational schedule (on and off duty) of subordinate staff.
- Bachelor’s degree in Electrical Engineering (Power Systems) is mandatory.
- Master’s degree is mandatory.
- Multicultural experience is mandatory.
- A minimum of 10+ years of experience in electrical design engineering (power systems) in the Oil & Gas industry.
- Proficient in Microsoft Office Suite (Excel, PowerPoint, Word).
- Proven experience leading multidisciplinary design teams in the execution of complex projects.
- Strong knowledge of industry standards and regulatory requirements (e.g., ASME, API, ISO, ANSI, etc.).
- Familiarity with design software tools (e.g., AutoCAD, PDS, Revit, etc.).
- Project management skills, including the ability to manage budgets, schedules, and resources.
- Proven experience to establish and oversee management of change (MOC) procedures.
- Experience with Installation, Commissioning and Factory Acceptance Test (FAT) and Site Acceptance Tests (SAT)
- Substation 11kV, 33kV, 161kV
- Switchgear 11kV, 33kV
- LV MCC
- Power transformers up to 33kV
- Overhead lines up to 33kV
- Cable: control, low voltage, medium voltage
- Cable trays: control, low voltage, medium voltage
- Ground grid for power systems and electronic sytem
- Lightning protection system
- AC/DC control low voltage
- Protective relays:
- 24 - Volts per Hertz Relay
- 25 - Synchronizing or Synchronism-check Device
- 27 - Undervoltage Relay
- 27P – Phase Undervoltage
- 27S – DC Undervoltage Relay
- 27TN – Third Harmonic Neutral Undervoltage
- 27TN/59N – 100% Stator Earth Fault
- 27X – Auxiliary Undervoltage
- 27 AUX – Undervoltage Auxiliary Input
- 27/27X – Bus/Line Undervoltage
- 27/50 – Inadvertent Energization
- 32 – Directional Power Relay
- 32P – Directional Power
- 32R – Reverse Power
- 50 – Instantaneous Overcurrent Relay
- 50BF – Breaker Failure or LBB (Local Breaker Back-up)
- 50G – Ground Instantaneous Overcurrent
- 50N – Neutral Instantaneous Overcurrent
- 50NBF – Neutral Instantaneous Breaker Failure
- 50P – Phase Instantaneous Overcurrent
- 50SG – Sensitive Ground Instantaneous Overcurrent
- 50/27 – Inadvertent Energization
- 50/51 – Instantaneous / Time-delay Overcurrent relay
- 50/74 – CT Trouble
- 50/87 – Instantaneous Differential
- 51 – AC Time Overcurrent Relay
- 51C – Voltage Controlled Time Overcurrent
- 51G – Ground Time Overcurrent
- 51LR – AC Inverse Time Overcurrent (Locked Rotor) Protection Relay
- 51N – Neutral Time Overcurrent
- 51P – Phase Time Overcurrent
- 51R – Locked / Stalled Rotor
- 51V – Voltage Restrained Time Overcurrent
- 51Q – Negative Sequence Time Overcurrent
- 52 - AC Circuit Breaker
- 52a – AC Circuit Breaker Position (contact open when circuit breaker open)
- 52b – AC Circuit Breaker Position (contact closed when circuit breaker open)
- 55 – Power Factor Relay
- 56 – Field Application Relay
- 57 – Short-Circuiting or Grounding Device
- 59 – Overvoltage Relay
- 59B – Bank Phase Overvoltage
- 59N – Neutral Overvoltage
- 59NU – Neutral Voltage Unbalance
- 59P – Phase Overvoltage
- 59X – Auxiliary Overvoltage
- 59Q – Negative Sequence Overvoltage
- 60 – Voltage or Current Balance Relay
- 60N – Neutral Current Unbalance
- 60P – Phase Current Unbalance
- 64 – Ground Protective Relay
- 64F – Field Ground Protection
- 64R - Rotor Earth Fault
- 64REF - Restricted Earth Fault Differential
- 64S - Stator Earth Fault
- 64S – Sub-harmonic Stator Ground Protection
- 64TN – 100% Stator Ground
- 67 – AC Directional Overcurrent Relay
- 67G – Ground Directional Overcurrent
- 67N – Neutral Directional Overcurrent
- 67Ns - Earth Fault Directional
- 67P – Phase Directional Overcurrent
- 67SG – Sensitive Ground Directional Overcurrent
- 67Q – Negative Sequence Directional Overcurrent
- 81 – Frequency Relay
- 81O – Over Frequency
- 81R – common industry use for Rate Of Change Of Frequency Relay (ROCOF)
- 81U – Under Frequency
- 87 – Differential Protective Relay
- 87B – Bus Differential
- 87G – Generator Differential
- 87GT – Generator/Transformer Differential
- 87L – Segregated Line Current Differential
- 87LG – Ground Line Current Differential
- 87M – Motor Differential
- 87N – Neutral Differential Protection / Restricted Earth Fault (REF) see also 87RGF
- 87O – Overall Differential
- 87PC – Phase Comparison
- 87RGF – Restricted Ground Fault see also 87N
- 87R – Restrained Differential
- 87S – Stator Differential
- 87S – Percent Differential
- 87T – Transformer Differential
- 87U – Unrestrained Differential
- 87V – Voltage Differential
- Strategic Vision: Lead projects aimed at enhancing efficiencies through refined processes and procedures.
- Strong Leadership: Capable of addressing technical, financial, and HR challenges in a dynamic business environment.
- Analytical Expertise: Excellent analytical skills with a focus on data analysis and process optimization.
- Attention to Detail: Ensure accuracy and compliance in all documentation and processes.
- Confidentiality and Integrity: Proven ability to manage sensitive information professionally and confidentially.
- Exceptional Communication Skills: Strong interpersonal abilities to effectively engage with employees and stakeholders at all levels.
- Problem-Solving Ability: Demonstrated capacity to analyze complex issues and develop practical solutions.
- Change Leadership: Experience in spearheading change initiatives and fostering a culture of continuous improvement.
- Diligent Project Management: Effectively manage multiple projects and ensure timely delivery.
- Technology Optimization: Navigate complexities and drive efficiency through technological advancements.
- Organizational Skills: Strong planning, organizational, and time management skills, with the ability to coordinate activities across various disciplines.
Ghanahires